Availability: | |
---|---|
Quantity: | |
These rubber cables are designed to provide high flexibility and have the capacity to withstand weather, oil/grease, mechanical and thermal stresses.
Key features include:
- High Flexibility: The rubber cable construction allows for superior bendability and maneuverability, making them easy to install and route.
- Weather Resistance: The robust rubber insulation protects the cables from the elements, ensuring reliable performance in diverse weather conditions.
- Oil and Grease Resistance: The cables can withstand exposure to industrial fluids, such as oil and grease, without compromising their integrity.
- Mechanical Durability: The cables are built to endure mechanical stresses, impacts, and abrasion, ensuring a long service life.
- Thermal Stability: The cables can operate reliably across a broad temperature range, from extreme cold to high heat.
These Rubber Cables are suited for a variety of applications, including:
- Handling Equipment: Powering mobile and stationary material handling machinery in warehouses and production facilities.
- Mobile Power Supplies: Providing reliable power for worksite tools, equipment, and temporary power setups.
- Stage and AV Systems: Delivering power to stage lighting, sound systems, and other audio-visual equipment in event and entertainment settings.
- Port Areas and Dams: Supplying electricity in harsh industrial environments, such as ports, dams, and other water-adjacent facilities.
- Drainage and Water Treatment: Functioning reliably in wet and corrosive settings, such as wastewater treatment plants and drainage systems.
- Cold Environments: Maintaining performance in extreme low-temperature conditions, such as in refrigerated warehouses or outdoor winter applications.
- Severe Industrial Settings: Withstanding the rigors of demanding industrial applications, including mining, manufacturing, and heavy construction.
Standard
These Round Flexible Rubber Cables comply with standards such as IEC245, BS6195, BS EN 50525-2-21, BS EN 50525-3-21, VDE, and CENELEC.
Voltage Rating:Uo/U 450/750V
Conductor:Class 5 flexible copper
Temperature Rating
Fixed: -30°C to +60°C
Fixed protected installations: +85°C
Flexed: -15°C to +60°C Minimum
Bending Radius
Fixed: 4 x overall diameter
Flexed: 6 x overall diameter
1. class 5 copper conductor
2. rubber insulation
3. rubber sheath
1 | 2 | 3 | 4 |
Number and nominal sectional area of conductors | Thickness of insulation | Thickness of sheath | Maximum resistance of conductor at 20℃ |
mm2 | mm | mm | Ω/km |
1x1.5 | 0.8 | 1.2 | 13.3 |
1x2.5 | 0.9 | 1.2 | 7.98 |
1x4 | 1.0 | 1.2 | 4.95 |
1x6 | 1.0 | 1.2 | 3.30 |
1x10 | 1.2 | 1.4 | 1.91 |
1x16 | 1.2 | 1.4 | 1.21 |
1x25 | 1.4 | 1.6 | 0.780 |
1x35 | 1.4 | 1.6 | 0.554 |
1x50 | 1.6 | 1.8 | 0.386 |
1x70 | 1.6 | 1.8 | 0.272 |
1x95 | 1.8 | 2.2 | 0.206 |
1x120 | 1.8 | 2.2 | 0.161 |
1x150 | 2.0 | 2.5 | 0.129 |
1x185 | 2.2 | 2.7 | 0.106 |
1x240 | 2.4 | 3.0 | 0.0801 |
2x1.5 | 0.8 | 1.5 | 13.3 |
2x2.5 | 0.9 | 1.7 | 7.98 |
2x4 | 1.0 | 1.8 | 4.95 |
2x6 | 1.0 | 2.0 | 3.30 |
2x10 | 1.2 | 3.1 | 1.91 |
2x16 | 1.2 | 3.3 | 1.21 |
2x25 | 1.4 | 3.6 | 0.780 |
3x1.5 | 0.8 | 1.6 | 13.3 |
3x2.5 | 0.9 | 1.8 | 7.98 |
3x4 | 1.0 | 1.9 | 4.95 |
3x6 | 1.0 | 2.1 | 3.30 |
3x10 | 1.2 | 3.3 | 1.91 |
3x16 | 1.2 | 3.5 | 1.21 |
3x25 | 1.4 | 3.8 | 0.780 |
4x1.5 | 0.8 | 1.7 | 13.3 |
4x2.5 | 0.9 | 1.9 | 7.98 |
4x4 | 1.0 | 2.0 | 4.95 |
4x6 | 1.0 | 2.3 | 3.30 |
4x10 | 1.2 | 3.4 | 1.91 |
4x16 | 1.2 | 3.6 | 1.21 |
4x25 | 1.4 | 4.1 | 0.780 |
5x1.5 | 0.8 | 1.8 | 13.3 |
5x2.5 | 0.9 | 2.0 | 7.98 |
5x4 | 1.0 | 2.2 | 4.95 |
5x6 | 1.0 | 2.5 | 3.30 |
5x10 | 1.2 | 3.6 | 1.91 |
5x16 | 1.2 | 3.9 | 1.21 |
5x25 | 1.4 | 4.4 | 0.780 |